Furnace repair in Dallas for the few weeks a year heat really matters

A condensing gas furnace in a utility room, its white vent pipes and metal ducts above it

Dallas heating gets less use than the AC and less attention, which is exactly why it fails when it is needed. January averages a high of 57.7 F and a low of 37.9 F, and the coldest night of a typical year is around 19 F. Most of the winter is mild. Then a front comes through, freezing rain coats the roads, and a furnace that sat for ten months has to run all night. In February 2021 the cold went far past that: DFW Airport reached minus 2 F on February 16, the coldest in North Texas in 72 years, and more than 4.5 million Texas homes and businesses lost power, some for several days.

Dallas HVAC Service is a free referral service: your request goes to an independent licensed HVAC company serving Dallas, which diagnoses the system and quotes any work itself. This page covers the three kinds of heat you find in Dallas houses, what fails in each, what you can check safely, and how to get ready before the next hard freeze.

Furnace, heat pump or heat strips: which one do you have?

Look at the thermostat and the equipment. A gas furnace has a flue pipe and a gas line, usually in the attic, a closet or the garage. A heat pump has an outdoor unit that runs in cold weather too, and its thermostat often shows Emergency Heat or Aux. Some houses have an electric air handler with heat strips and no heat pump at all.

TypeHow it heatsWhat fails mostWhat you notice
Gas furnaceBurns natural gas; a blower pushes air across a heat exchangerHot surface ignitor, flame sensor, pressure switch, clogged filterClicks and tries to light, then shuts down; or blows cold air
Heat pumpMoves heat from outdoor air into the house with refrigerantDefrost controls, reversing valve, outdoor fan, low chargeLukewarm air, ice that does not clear from the outdoor coil, Aux heat running constantly
Emergency or auxiliary heatElectric heat strips in the air handlerBurnt-out strips, sequencers, breakers sized for the loadHeat pump runs but air never gets warm; a tripped breaker in the panel

Why the first cold front catches systems out

Gas furnaces

A modern furnace lights itself with a hot surface ignitor, a small element that glows before the gas valve opens. Ignitors crack with age. Once the flame lights, a flame sensor proves it; when the sensor is coated, the furnace lights for a few seconds and shuts off, then tries again. A pressure switch checks that the flue is drawing; a blocked vent or a cracked hose stops the sequence. A filter that clogged all through the cooling season can make the furnace overheat and shut itself off on its high-limit switch.

Heat pumps

In cold, damp weather the outdoor coil of a heat pump frosts over. The system reverses briefly to melt it, which is the defrost cycle, and you may see steam rising from the unit. That is normal. A solid block of ice that never clears, or an outdoor fan that will not turn, is not. A heat pump also delivers air that feels cooler than a furnace’s, and in a hard freeze it leans on its electric backup heat, which can run up the bill.

Emergency heat

Emergency heat switches the heat pump off and runs only the electric strips. It is meant for when the outdoor unit has failed or is iced solid. Running it all winter by mistake is an expensive habit; check the thermostat mode if the bill jumps.

A household furnace cabinet with its service panel off, showing the control board and wiring
A gas furnace with its service panel open

The cold-snap checklist

This is the extra this page offers: what to check yourself before you ask for a visit, and what to do before a hard freeze arrives.

Safe owner checks when there is no heat

  1. Thermostat: set to Heat (not Cool or Off), the set point above room temperature, batteries fresh.
  2. Filter: replace it if you cannot see light through it. A choked filter can shut a furnace down on its safety limit.
  3. Breakers: check the furnace or air handler breaker and, for a heat pump, the outdoor unit breaker. Reset a tripped one once only.
  4. Furnace switch: a light-style switch on or near the furnace must be on. Service panels on many furnaces have a door switch, so the cover must be seated.
  5. Gas: make sure the gas valve at the furnace is open (handle in line with the pipe) and that other gas appliances work.
  6. Heat pump outdoor unit: clear snow, ice or leaves from around it. Do not chip ice off the coil.

If the furnace still will not run, stop there. Gas valves, burners, heat exchangers and venting are licensed work. If you smell gas, leave the house and call the gas utility from outside; do not touch switches.

Carbon monoxide: the alarm is not optional

The EPA describes carbon monoxide as an odorless, colorless and toxic gas that is impossible to see, taste or smell. Any house with a gas furnace, gas water heater, gas range or an attached garage should have working CO alarms. The EPA points to the Consumer Product Safety Commission’s alarm guidance; follow the alarm maker’s instructions for placement, and test them when you change your clocks. If an alarm sounds, get everyone outside and call for help from there.

Never

Do not heat the house with a gas oven, a grill or a generator, and never run a generator in a garage, even with the door open. Those are common causes of carbon monoxide trouble during power outages like the one in February 2021.

Before a hard freeze

  • Have the heat checked when the weather first turns, before every company in town is busy.
  • Replace the filter and keep a spare on hand.
  • Know where the main water shutoff is, and disconnect garden hoses from outdoor faucets.
  • Wrap or cover exposed pipes in the attic, garage and outside walls with insulation.
  • On the coldest nights, open cabinet doors under sinks on outside walls and let a faucet drip.
  • If the power goes out, close off unused rooms and keep doors shut to hold heat in the rooms you use.
  • Keep the outdoor heat pump clear, and do not cover it while it is in use.

No heat, or a furnace that lights and quits? Ask an independent licensed company to look.

What a technician checks on a heating call

  • The ignition sequence: inducer motor, pressure switch, ignitor, gas valve and flame sensor, in order
  • The heat exchanger and burners, and the flue and venting for blockage or separation
  • Temperature rise across the furnace, compared with the maker’s range on the label
  • For a heat pump: defrost operation, reversing valve, outdoor fan and the refrigerant charge
  • Heat strips, sequencers and the breakers that feed them
  • Thermostat wiring and settings, including the Aux and Emergency heat staging

Ask what failed and how it was tested, and get the price in writing. Gas furnace work in Texas falls under the same TDLR air conditioning and refrigeration licensing as cooling; Occupations Code section 1302.251 requires a licensed ACR contractor for this work, and you can check the license on TDLR’s Verify a License search.

Repair it or plan a replacement?

A cracked ignitor or a dirty flame sensor is a small repair at any age. A cracked heat exchanger, a failing inducer on an old furnace, or a heat pump with a failed compressor is where the conversation turns to replacement. Many Dallas owners replace the furnace and AC together, or move to a heat pump with gas backup. The AC installation in Dallas page has the bid checklist and the AC replacement cost in Dallas page explains what moves the price. If the problem is cooling rather than heat, start with AC repair in Dallas.

For landlords and tenants

Texas Property Code section 92.052 requires a landlord to make a diligent effort to repair a condition that materially affects the physical health or safety of an ordinary tenant, after the tenant gives notice and is current on rent. Tenants: put the notice in writing and keep a copy. Landlords: work on a rental you own must go through a licensed ACR contractor, since the homeowner exemption covers only the home you live in.

Common questions

Why does my furnace light and then shut off after a few seconds?

A dirty or failing flame sensor is the most common cause. A blocked vent or a pressure switch problem can do it too. It needs a technician.

Is steam from my heat pump in cold weather normal?

Yes, during a defrost cycle. A coil that stays solid with ice, or a fan that will not turn, is not normal.

When should I use emergency heat?

Only when the outdoor unit has failed or is iced solid. It runs the electric strips alone and costs more to run.

Does this site send a technician?

No. Dallas HVAC Service is a free referral service. An independent licensed HVAC company serving Dallas contacts you and does the work.